Table 1

Calculated conductance slopes for Ca2+-activated leakage currents induced by δ-HCH

Ionic Condition (cis/trans)Current ModifierCurrent Slope
pA/mV
500 mM CsClControl0.01  ± <0.01
(Fig. 2A)50 μM γ-HCH + 50 μM Ca2+(cis)0.02  ± 0.01
(Fig. 3A)50 μM δ-HCH + 50 μM Ca2+ (cis)1.28  ± 0.05
100 mM CsClControl0.01  ± <0.01
(Fig. 6A)50 μM δ-HCH (cis)0.09  ± <0.01
 +50 μM Ca2+(cis)1.33  ± 0.08
 +350 μM Ca2+(cis)4.70  ± 0.22
 +700 μM Ca2+(cis)6.15  ± 0.10
 +1.15 mM Ca2+(cis)7.49  ± 0.09
 +1.65 mM Ca2+(cis)7.89  ± 0.11
1 mM CaCl2 Control0.07  ± 0.01
(Fig. 5A)50 μM δ-HCH (cis)0.35  ± 0.01
100 mM CsMeSo3 Control0.04  ± <0.01
(Fig. 5B)50 μM δ-HCH (cis)0.22  ± 0.01
 +50 μM Ca2+ (cis)1.37  ± 0.04
100 mM KClControl0.27  ± <0.01
(Fig. 2B)50 μM δ-HCH (cis)0.49  ± 0.01
 +50 μM Ca2+(cis)4.25  ± 0.03
Control0.09  ± <0.01
(Fig. 3B)50 μM γ-HCH (cis)0.01  ± <0.01
 +50 μM Ca2+ (cis)0.01  ± <0.01
100 mM NaClControl0.14  ± <0.01
(Fig.2C)50 μM δ-HCH (cis)0.18  ± 0.01
 +50 μM Ca2+ (cis)0.66  ± 0.01
(Fig. 3C)Control0.01  ± <0.01
50 μM γ-HCH (cis)0.01  ± <0.01
 +50 μM Ca2+(cis)0.01  ± <0.01