Table 1

PK parameters for MPL disposition (dose = 50 mg/kg) in rats

Parameters (U)Value
Biexponential fitting
C 1 (μg/ml)56.3
C 2 (μg/ml)14.5
 λ1(h−1)9.88
 λ2 (h−1)1.22
Area/moment analysis
 AUC (μg · h/ml)17.6
 AUMC (μg · h−2/ml)10.3
 MRT (min)35.2
PK analysis
T ½(min)34.1
 CL (l/h/kg)2.85
V C(l/kg)0.71
V ss (l/kg)1.67