Table 1

Comparison of carotid blood flow and estimated shear rates in arteriovenous shunt and CFR models

AVS1-aCFRP Value
PSTSTAVS vs. PSTAVS vs. STPSTvs. ST
Number615
Body weight (kg)2.6  ± 0.12.78  ± 0.1
Blood flow (ml/min)26.7  ± 1.524.8  ± 1.214.9  ± 1.1NS<0.05<0.05
Shear rate (sec−1)566 (477–637)527 (316–640)39,561 (21,619–61,009)NS<0.05<0.05

Values are mean ± S.E.M. or ranges (in parentheses) for estimated shear rates.

  • 1-a AVS, arteriovenous shunt; PST, prestenosis; ST, stenosis.