TABLE 1

Current imaging modalities of interest in pulmonary drug research and discovery

TechniqueSpatial Resolution and Time ScaleApplicationMain Characteristics
Small RodentsHumans
CT50–100 μm; seconds to minutes∼600 μm; < 1 minAnatomical, functionalIonizing radiation; poor soft tissue contrast
ScintigraphyNo∼20 mm;FunctionalPlanar information
SPECT (low-energy γ-rays)≤1 mm; ∼20 min∼10 mm; 10–30 minFunctionalIonizing radiation; radioisotopes have longer half-lives than those used in PET; sensitivity 10 to 100 times smaller than PET
PET (high-energy γ-rays)1–2 mm; ∼20 min∼4 mm; ∼20 sMetabolic, functional, molecularIonizing radiation; high sensitivity (picomolar concentrations); cyclotron needed
MRI80–140 μm; seconds to hours1.5 mm; seconds to minutesAnatomical, functional, molecularHigh spatial resolution and soft tissue contrast; low sensitivity
NIRF optical imaging1–3 mm; seconds to minutesNoMolecularHigh sensitivity (nanomolar concentrations); maximal penetration depth <10 cm