|
|
|
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
BEHAVIORAL PHARMACOLOGY
Department of Psychology, Rutgers University, New Brunswick, New Jersey
Received for publication
August 9, 2007
Accepted
November 6, 2007.
| Abstract |
|---|
|
|
|---|
Nonetheless, it is not yet clear what changes occur in striatal firing during this transduction. Previous studies investigating effects of psychomotor stimulants on striatal neural activity have yielded a mixture of results, including suppression (Rebec and Segal, 1978
; Nisenbaum et al., 1988
), excitation (Haracz et al., 1993
; West et al., 1997
), or both (Trulson and Jacobs, 1979
; Ryan et al., 1989
; Pederson et al., 1997
). Studies that reported exclusively suppression were conducted during anesthesia, which itself suppresses spontaneous and sensory-evoked striatal firing (West, 1998
). Therefore, it is desirable to conduct such studies in freely moving animals. Alteration of motor behavior by psychomotor stimulants introduces the need to consider the fact that most striatal neurons naturally fire phasically in relation to movement (e.g., Crutcher and DeLong, 1984
; Mittler et al., 1994
; Cho and West, 1997
). Trulson and Jacobs (1979
) recognized the importance of assessing drug effects on firing by comparing firing during similar movements before and after injection. Because some previous studies did not adequately do so, the mixture of effects that have been reported may involve the use of anesthesia or lack of adequate control for movement-related changes in firing. Thus, consideration of these factors is critical in the design of studies assessing striatal activity associated with the use of psychomotor stimulants.
A brief report from this laboratory examining cocaine's acute effects on firing rates of striatal neurons related to head movement during stereotyped head bobbing demonstrated a firing rate-dependent effect (Pederson et al., 1997
). Firing during movements that were normally associated with low firing rates was elevated, whereas firing during movements that were normally associated with high firing rates was less elevated or suppressed by cocaine. This effect was more pronounced at higher doses.
To further investigate the role of striatal neurons in cocaine-induced stereotypy, in the present study, we examined changes in firing rate of neurons related specifically to licking in the ventrolateral striatum of awake, freely moving rats during a licking task. After 1 h in the task, rats received an acute injection of 0 (saline) 5, 10, or 20 mg/kg cocaine and then continued in the task for 1 to 3 h. The design allowed for drug-induced licking movement and at the same time included several levels of strategy aimed at minimizing the influence of movement variations on the assessment of cocaine's effect on striatal firing.
The ventrolateral striatum contains neurons that fire specifically in relation to orofacial sensorimotor activities such as licking (Crutcher and DeLong, 1984
; Mittler et al., 1994
; Cho and West, 1997
). Specific sensorimotor firing of these striatal projection neurons is mediated by inputs from primary somatosensory and motor cortices (West, 1998
, and references therein), thus providing a useful model for studying corticostriatal throughput. Because neurons that fire phasically in relation to sensorimotor activity constitute at least 50 to 70% of the neuronal population in the lateral striatum (Cho and West, 1997
), it is likely that lick-related neurons are key to the ventrolateral striatum's role in psychostimulant-induced oral stereotypy. It is therefore important to better clarify how their firing patterns are altered in the presence of these commonly abused drugs.
| Materials and Methods |
|---|
|
|
|---|
Rats were individually housed and maintained on a reversed light/dark cycle (on, 8:00 PM/off, 8:00 AM). After 1 week of recovery, animals were water deprived and maintained at 82% of their post-surgery weight. Food was provided ad libitum. All efforts were made to minimize animal suffering and to use only the number of animals necessary to produce reliable scientific data in accordance with the National Institute of Health guide for care and use of laboratory animals (NIH Publication 80-23).
Microdrive Recording
For rats at doses 5, 10, and 20 mg/kg, on the day of a recording session, the microdrive was equipped with a tungsten microelectrode (10 Mohm; Frederick Haer, Brunswick, ME) and attached to the base on the rat's skull. The rat was placed in a transparent, Plexiglas recording chamber (23.5 x 17.4 x 43 cm) and connected to a harness, which was connected at its other end to a commutator allowing free movement of the rat. The electrode was lowered to the ventrolateral striatum in small increments over several hours by manual rotation of the outer cylinder of the microdrive (400 µm/rotation) without rotation of the electrode, providing a vertical recording track. Details regarding recording procedures and on-line verification of the microelectrode's position have been described previously (Mittler et al., 1994
; Cho and West, 1997
). Neural signals recorded from the microelectrode were amplified and filtered (450 Hz to 10 kHz) and then were digitized (62.5-kHz sampling frequency) and stored for off-line analysis using the software of Datawave Technologies (Berthoud, CO).
Microwire Recording
For rats at dose 0, microwire recording technology was utilized, allowing simultaneous recording from chronically implanted multiple electrodes with less risk of having to discard data due to loss of single unit isolation. An array of 12 microwires was implanted into the ventrolateral striatum, where lick-related neurons are densely located in clusters (Cho and West, 1997
). On the day of a recording session, the rat was placed in the recording chamber. A harness was at its one end attached to the microwire array and connected at its other end to a commutator. Neural signals were led through an amplifier that differentially amplified them against background signals from another electrode within the array that did not exhibit neural signals. Neural signals were then led through a band pass filter, and were digitized (62.5-kHz sampling frequency for each wire) and stored for off-line analysis using the Datawave software. Neural parameters, e.g., waveforms and firing rates, of striatal neurons recorded by moveable microelectrodes or microwires were similar, allowing for pooling data that were collected from both types of recordings in off-line analysis.
Apparatus
A water spout was positioned 7 mm outside the front wall of the recording chamber. The chamber and licking apparatus were designed to restrict sensorimotor variables such as body and head position in front of the spout, while still allowing for the animal's free movement. Silicon tubing (1.6 mm inside diameter) was used to connect a container filled with tap water and a solenoid valve (General Valve, Fairfield, NJ) to the stainless steel drinking spout (Small Parts Inc., Miami, FL). A small hole (7-mm diameter) in the Plexiglas wall allowed the rat's tongue access to water drops at the tip of the spout. To register each lick, a light beam carried by fiber optic and positioned above and below the spout was fed into a diode tracker. Thus, beginning at the inside surface of the front wall, the tongue crossed the light beam at 5 mm and reached the spout at 7 mm. The presence of the light beam (absent only while the tongue was interrupting it during a lick) was recorded and time-stamped every 16.6 ms by the same clock that time-stamped the neural waveforms (Discovery software; Datawave Technologies). Water delivery was controlled by a pulse from the computer that opened the solenoid for 35 ms, delivering one drop of approximately 5 µl through the spout (one water delivery). Time between water deliveries was pseudorandom, ranging from 6 to 12 s with a mean of 9 s. An audible tone (35 ms, 70 dB), consisting of mixed frequencies (500 Hz and 3 KHz), was presented through a speaker mounted above the chamber during activation of the solenoid to provide an audible cue corresponding to the activation of the quiet solenoid. All recording sessions were videotaped to allow for off-line monitoring of behavior. White noise (60 dB outside the Plexiglas chamber) was used to minimize any disturbances from outside the experimental room.
Video Analysis
A computerized system was used for analyzing relationships between neural activity and videotaped licking. A video camera (Panasonic WV-BL202 CCTV; Panasonic Corporation, Secaucus, NJ) with zoom lens focused on the spout and a videocassette recorder (JVC Super VHS HR S7200U; JVC Company of America, Wayne, NJ) provided a resolution of tongue movement of 30 frames/s. The clock in the computer that time-stamped neural data also sequentially time-stamped each frame via a video frame counter (Thalner Electronics VC-436; Thalner Electronic Laboratories, Inc., Ann Arbor, MI), which displayed the number of each frame on the TV monitor. Using off-line videotape analysis, a specific motor event could be isolated on a single video frame. All frames in which the event recurred were compiled and entered into the computer as nodes. Raster displays and perievent time histograms (PETHs) were constructed around the nodes to depict unit activity time-locked to the motor event. Although each video frame was 33 ms in duration, greater resolution was routinely achieved by interpolating between frames. The maximum resolution of movement employed was in increments of 11 ms, with a maximum error of ±1 increment. Video-generated PETHs were used to verify the accuracy of PETHs generated by the diode tracker.
Behavioral Paradigm
Prior to each recording session, a complete sensorimotor exam was conducted for every electrode that exhibited neural activity to determine whether neural firing was related to sensorimotor activity of any body part(s) (Mittler et al., 1994
; Cho and West, 1997
). During the exam, drops of water were manually delivered to determine whether neural firing was related to licking, as the experimenter listened through headphones to the output of the filter/amplifier. Only lick-related neurons that increased firing rate during licking and did not increase firing rate during any nonoral behavior were recorded during a recording session.
Each recording session comprised three time epochs. 1) The precocaine time epoch (T1) lasted 1 h and consisted of three 15-min water-on phases (100 water deliveries in each), alternating with three 5-min water-off phases (no water-deliveries). The licking response was readily shaped during the first 2 min of the first water-on phase in T1. 2) The cocaine time epoch (T2) began with the injection of either saline (0.9%, 0.5 ml/kg i.p.) or one dose of cocaine HCl (5, 10, or 20 mg/kg, calculated according to the salt weight of the drug, injected in 0.5 ml/kg volume of 0.9% saline i.p.). T2 lasted 1 h and was programmed identically to T1 with respect to water-on/water-off phases. 3) The recovery time epoch (T3) was the 3rd or 4th h following cocaine injection. T3 was also programmed identically to T1 with respect to water-on/water-off phases. For rats at doses 5, 10, and 20 mg/kg: 1) T1 began with the injection of saline (0.9%, 0.5 ml/kg i.p.), 2) T3 was conducted to examine the recovery of licking behavior and neural firing from the effects of cocaine in T2, and 3) up to three sessions were conducted on each rat to increase the data yield, with at least 4 weeks between any two sessions. No particular dose sequence was used. For rats at dose 0 (saline), only one session was conducted on each rat.
Histology
Following the last microdrive recording session, a lethal injection of sodium pentobarbital (150 mg/kg i.p.) was given, and an electrolytic lesion was made by passing anodal current (50 µA for 4 s) through a stainless steel, insulated wire (250 µm) that was mounted in the microdrive and positioned at the same location at which a neural recording had been obtained. Following the last microwire recording session, a lethal injection of sodium pentobarbital (150 mg/kg i.p.) was given, and anodal current was passed through each of the 12 microwires in the array to make an electrolytic lesion at the tip of each microwire. Then, intracardial perfusion was performed on each rat using 10% formalin-saline. The brain was extracted and fixed in a solution of 30% formalin and sucrose. Coronal sections (50 µm) through the striatum were mounted. The iron deposit at each lesion was stained with a solution of 5% potassium ferricyanide and 10% HCl, and the tissue was counterstained with 0.2% solution of Neutral Red. The location of each recorded neuron (lesion) was determined by reconstructing its three-dimensional position within the striatum according to the brain atlas of Paxinos and Watson (2005
). Recorded neurons corresponding to lesions that were found outside the ventrolateral striatum were discarded.
Behavioral Analysis
Analysis of Number of Licks during Water-Off Phases. The number of licks during water-off phases was used as a measure of licking stereotypy. Cocaine-induced stereotypy was assessed as the change in the number of licks during water-off phases from T1 to T2. A standardized value, [L2/(L1 + L2) - 0.5], was calculated for every recording session, with L1 equal to the number of licks during water-off phases in T1, and L2 equal to the number of licks during water-off phases in T2. Therefore, a standardized value of zero represents no change in the number of licks during water-off phases from T1 to T2, and a positive or negative standardized value represents an increase or decrease of the number of licks during water-off phases from T1 to T2, respectively. A one-way ANOVA with
level of 0.05 was conducted to evaluate differences in this measure across doses. Post hoc Bonferroni tests were used to evaluate pair-wise differences between doses if any significant differences across doses were found by ANOVA. Furthermore, to assess reversal of licking stereotypy in T3, a similar standardized value of change in the number of licks during water-off phases between T1 and T3, [L3/(L1 + L3) - 0.5], was calculated for every dose group that showed a significant change between T1 and T2 relative to dose 0. Then, a within-subjects comparison was conducted using a paired Student's t test to compare the standardized value of change in the number of licks during water-off phases between T1 and T2 versus that between T1 and T3.
Four experimental sessions at dose 20 were excluded only from this particular analysis of stereotypy, because video analysis confirmed that these rats extensively engaged in stereotypic behaviors such as head bobbing that competed with licking the spout. This resulted in substantial reductions in licking during both water-on and water-off phases in T2. Thus, the number of licks in water-off phases was not an appropriate measure of stereotypy for these rats. Nonetheless, the presence of stereotypic behaviors in T2 and the reversal in T3 were confirmed in these four sessions via video analysis. Despite the presence of competing stereotypic behaviors, sufficient numbers of licks at the spout were exhibited to allow the data acquired in these sessions to be included in all other analyses, including the behavioral analysis of lick parameters and the neural analysis of matched pairs (see below).
Analysis of Behavioral Parameters of Each Lick. The onset of each lick was defined as the time at which the fiber optic light beam was interrupted (blocked). The end time of each lick was defined as the time at which the light beam became unblocked. Three behavioral parameters were calculated for every lick: 1) lick duration, time between the onset and end time of a lick. Lick duration ranged from 0 to 117 ms and was divided into 7 levels with equal increments of 16.6 ms from low to high; 2) lick period, time between the onset of the present lick and onset of the next lick. Period ranged from 84 to 267 ms and was divided into 12 levels with equal increments of 16.6 ms from low to high; and 3) interlick interval (ILI), time between the end of the present lick and onset of the next lick. ILI ranged from 0 to 250 ms and was divided into 15 levels with equal increments of 16.6 ms from low to high. By definition, for each lick, period was the sum of duration and ILI.
Based on its duration and period (ILI was therefore implicitly involved), every lick of a session was sorted into one cell of a matrix having seven rows (duration) and 12 columns (period). For each session, one matrix was generated for T1, one for T2, and one for T3. Detailed video analyses of tongue movement were compared with graphic frequency distributions of all recorded periods in the present paradigm. This analysis reveled that a single or consecutive undetected lick(s) that did not reach the lick sensor to break the light beam (e.g., a short lick or lateral tongue movement) resulted in a long interval (e.g., >270 ms) between the preceding detected lick and the subsequent detected lick. Such occurrences, which were frequent, would cause an artificial period of the preceding lick that was longer than its actual period. An artificial, long period could also be caused if the rat paused between consecutive licks. Therefore, an upper limit value of 270 ms for period was used to eliminate these artificial, long intervals to obtain an accurate measurement of period.
A multivariate analysis of variance (MANOVA) was performed on each of the three parameters to examine changes in that parameter between T1 and T2 across doses. For every recording session, the percentage of licks in every level of the parameter (7, 12, and 15 levels for lick duration, period, and ILI, respectively) during T1 through T2 was calculated. These percentage values were used as the dependent variable in the MANOVA for this parameter. The independent variables in the MANOVA were time (T1 and T2), dose, levels of the parameter, and two- and three-way interaction terms of these independent variables. Furthermore, if the MANOVA revealed any significant effect of cocaine on a parameter across doses, mean percentages of licks of all recording sessions in T1 and T2 were separately plotted against the levels of that parameter at different doses to illustrate the pattern of change in this parameter from T1 to T2 across doses. In addition, a second MANOVA between T1 and T3 was performed on that parameter to examine the recovery of that parameter across doses of cocaine. Of nine recording sessions at dose 20, one was excluded from the analysis of reversal because data were not available in T3 for this recording session.
We also used video analysis to measure the distance of individual licks by measuring whether or not the frontal portion of the tongue clearly and visibly extended through the hole in the front wall outside the chamber by greater than 3 mm (defined as a "long-distance lick"). For every recording session at dose 20, we examined 100 licks beginning at the 5th min of each water-on phase in T1 and T2. The percentages of long-distance licks in T1 and T2 were separately calculated by dividing the total number of long-distance licks in all three water-on phases of each phase by 300. The change of this value between T1 and T2 at dose 20 was assessed using a Wilcoxon signed ranks test.
Neural Analysis
Isolation of the Waveforms and Construction of Perievent Time Histograms for Single Neurons. After the session, a neuron's signals were isolated from background noise and from other neurons' signals using the "cluster cutting" process of the Datawave software. Waveforms of each neuron were analyzed using eight parameters: peak amplitude, valley amplitude, spike height, latency to peak, latency to valley, and voltages at three particular time points chosen based specifically on the individual waveform, as described in detail elsewhere (Tang et al., 2007
). Interspike interval analysis was also used to confirm that isolated waveforms in each case corresponded to those of a single neuron (i.e., no discharges occurred within the first 2 ms in the interspike interval histogram, representing a neuron's natural refractory period). Cocaine at high concentration interferes with Na+ channels, which could alter extracellular action potential waveforms and result in failures to detect discharges. Despite this possibility, our analyses showed that waveforms were unchanged following the high dose (see Pederson et al., 1997
).
A PETH that displayed neural firing forward and backward in time from onset of lick was constructed for each neuron recorded, using as nodes all licks from the entire session. These histograms were used to confirm that firing of each neuron analyzed was related to licking and to determine the time window in which the neuron's firing increased during the lick. In the PETHs, all lick neurons showed increased firing: some neurons increased firing before lick onset, some at onset, and some after onset. Therefore, analysis of neural firing was customized to each individual neuron by determining a time window of firing in the PETH using one of two methods: 1) a visual examination was performed on the PETH. The beginning of the time window was defined as the time (in milliseconds) at which neural activity showed a visually distinct increase in firing above the baseline preceding lick onset. If the increased firing returned to baseline at a time before the beginning of lick, then the end of the time window was set at the beginning of the lick. If the increased firing returned to baseline at a time near the end of lick, then the end of the time window was set at the end of the lick. If the increased firing rate returned to baseline at a time distant from the end of lick, then the time window ended at the time at which the increased firing returned to baseline; 2) a Wilcoxon analysis was used on the PETH. The beginning of the time window was defined as the time at which neural activity increased (p < 0.05, comparing two consecutive 20-ms bins at a time), and similarly the end of the time window was defined as the time at which the increased firing rate returned to the preincrease level (Peoples and West, 1996
). Both methods yielded similar results. In both methods, the beginning of the time window was not allowed to exceed a maximum of 80 ms prior to the onset of the present lick to assure that the time window of the present lick did not overlap with that of the previous lick.
Matched Pairs. All assessments of cocaine's effects on firing involved comparisons of "matched pairs," defined as follows. A neuron's firing rate (FR) during each lick was calculated by dividing the number of discharges that occurred during the specified time window of firing by the duration of that time window. Each lick from a given session was sorted into the matrix for the time epoch (T1, T2, or T3) during which the lick occurred. Mean FR was calculated for the licks (with the same duration and period) that were included in each cell of the matrix for each time epoch. To ensure an adequate sampling for a more accurate assessment of mean FR, five or more licks of a particular duration and period (i.e., five or more licks per cell) were required in each epoch to be included in the analysis. Licks with similar duration and period that occurred
five times in each epoch were matched between T1 and T2 or between T1 and T3 and were termed a matched pair. To illustrate this approach, Table 1 presents the matched pairs between T1 and T2 and those between T1 and T3 of a representative neuron.
|
|
For each neuron, the only method of comparing FR between pre- and postdrug epochs was by using matched pairs. This minimized the extent to which sensorimotor variability could influence our assessment of preversus postcocaine changes in firing.
Examining Changes in Mean Firing Rate of Individual Neurons from T1 to T2 across Doses with a Hierarchical Linear
Model. A hierarchical linear model (HLM) is appropriate for analyzing data with a hierarchical structure (Bryk and Raudenbush, 2002
). A two-level hierarchical structure existed in our neural data in which matched pairs were nested within individual neurons to which they belonged. Therefore, a two-level HLM was developed to model the two-level hierarchical neural data of matched pairs between T1 and T2.
Level 1 within-neuron model:
![]() | (1) |
![]() | (2) |
![]() | (3) |
Two regression equations were included in the level 2 between-neuron model. Each had three predictor variables and their interaction terms: dose, dose2, MT1FR, the interaction of dose and MT1FR, and the interaction of dose2 and MT1FR. To control against multi-collinearity caused by the interaction terms in the level 2 model, dose, dose2, and MT1FR were each centered around their means by subtracting the overall means from each value of these variables across all neurons (Bryk and Raudenbush, 2002
). The HLM allowed us to simultaneously model changes in average FR of individual neurons and changes in slope of the within-neuron regression via between-neuron regression eqs. 2 and 3, respectively. In eq. 2, β0i represented the predicted average T2FR of the ith neuron,
00 represented the intercept of the regression, other
s represented the regression parameters of corresponding variables in eq. 2, and the error term (u0i) represented the unexplained portion of between-neuron variance of the regression function in eq. 2. In eq. 3, β1i represented the slope of the within-neuron regression of the ith neuron,
10 represented the intercept of the regression, other
s represented the regression parameters of corresponding variables in eq. 3, and the error term (u1i) represented the unexplained portion of between-neuron variance of the regression function in eq. 3. This two-level HLM was fit on the neural data of matched pairs using the SAS PROC MIXED procedure (SAS Institute Inc., Cary, NC).
If the HLM on matched pairs between T1 and T2 found any significant effect of cocaine on the average FR of neurons in T2 across doses, analysis of reversal in T3 was performed by fitting another two-level HLM on matched pairs between T1 and T3 for neurons at doses 5, 10, and 20. In this HLM, the T3FR of matched pairs was used as the dependent variable in the level 1 within-neuron regression, and other predictor variables were kept the same.
Following each HLM analysis, we performed additional ordinary least squares linear regression analyses by regressing the average T2FR or T3FR on the average T1FR of neurons based on log10-transformed values at each dose. The R2 values and regression lines were compared across doses to demonstrate any effects of cocaine on the neuron's average firing rate in T2 or T3 that were revealed by the HLM analysis.
Examining Changes in Firing Rates of Matched Pairs from T1 to T2 of Individual Neurons across Doses. To examine the change in dispersion or variability in FR of matched pairs from T1 to T2 of individual neurons across doses, the S.D.s of T1FRs and T2FRs of all matched pairs were separately calculated for every neuron. A two-way repeated-measures ANOVA with dose as the between-neuron variable and time (T1 and T2) as the repeated-measure withinneuron variable was performed on these S.D.s.
To assess the predictability of T2FR of matched pairs from their T1FR within individual neurons, the T2FRs of matched pairs were linearly regressed on their T1FRs for every neuron. The R2 value of each regression function represented the proportion of total variance in T2FRs of all matched pairs that could be accounted for by their T1FRs for every neuron. A one-way ANOVA was performed on R2 values of neurons across doses.
To further examine the changes in FR of matched pairs from T1 to T2 of individual neurons across doses, two 2 x 4 analysis of covariance (ANCOVA) models were performed on "slow" and "fast" firing neurons, respectively. First, neurons were segregated into two categories: slow and fast firing neurons. This was done according to each neuron's average T1FR of all matched pairs, using as the cut point 1.00 impulses/s (Pederson et al., 1997
), which approximated the overall median (1.02 impulses/s) of the average T1FRs of all 70 neurons in the present study. Second, all matched pairs of each individual neuron were divided into two categories of T1FR matched pairs (low and high T1FR groups), using as the cut point the middle of the neuron's range of T1FRs by calculating: [(the neuron's maximum T1FR from among all its matched pairs)/2]. Third, for every neuron, the T1FR and T2FR of each matched pair were transformed by [(T2FR/(T1FR + T2FR)) - 0.5] to compute a standardized value that represented the magnitude of change in FR from T1 to T2 for each matched pair. Because this transformation was inappropriate for matched pairs with zero FR values in either T1 or T2, a constant of 0.01, the smallest decimal increment in FR observed in the present study, was added to T1FR and T2FR of every matched pair before the transformation to include all matched pairs into this analysis (Mosteller and Tukey, 1977
). Furthermore, to justify adding the constant 0.01, a thorough graphic examination was performed on every neuron to compare the patterns of change in the standardized values of its matched pairs before and after adding the constant. The results of this graphic analysis confirmed that adding the constant did not cause any differences in the patterns of change in the standardized values.
In both ANCOVAs (one for slow firing neurons and the other for fast firing neurons), the dependent variable was the standardized value of change from T1FR to T2FR of matched pairs. The independent variables were dose (0, 5, 10, and 20), T1FR group (low and high T1FR matched pairs), and the interaction between dose and T1FR group. The average T1FR of individual neurons (MT1FR) was included in each ANCOVA as a covariate to take into account the fact that matched pairs came from neurons with different average T1FRs. Post hoc Bonferroni tests were used to examine changes in FR of matched pairs at each cocaine dose relative to the saline group.
If the ANCOVA(s) revealed any significant effect of cocaine on FR of matched pairs within slow or fast firing neurons at any dose(s) in T2, analysis of reversal in T3 was performed separately for slow and fast firing neurons that exhibited stable neural activity in T3 at each dose. At each dose, matched pairs included in the analysis of reversal were those of T1 and T2 that also showed no less than five licks in T3. Similar to calculating the standardized value of change in FR between T1 and T2, a standardized value of change in FR for each matched pair between T1 and T3 was calculated. Then, for matched pairs of slow or fast firing neurons at each dose, a within-subject comparison was conducted using a Wilcoxon signed ranks test to compare the standardized value of change in FR of matched pairs between T1 and T2 versus that between T1 and T3. A significant result of this comparison would indicate a reversal of FR of matched pairs from T2 to T3 with respect to T1 at this dose. If the ANCOVA revealed a significant interaction between dose and T1FR group that indicated different effects of cocaine on low and high T1FR matched pairs at each dose, the comparison was performed separately for low and high T1FR matched pairs at each dose. If the interaction was not significant, the comparison was performed for all matched pairs by pooling low and high T1FR matched pairs at each dose.
| Results |
|---|
|
|
|---|
|
|
There was also a dose-dependent effect of cocaine on ILI, indicated by a significant three-way interaction among T1 to T2, dose, and levels of ILI [F(42,366) = 1.45, p < 0.05; Wilks' Lambda criterion, MANOVA]. As dose increased, cocaine systematically decreased the proportion of licks with shorter ILI and concurrently increased the proportion of licks with longer ILI in T2 relative to predrug values (Fig. 2B). There were no significant interactions (p > 0.61) or main effect (p > 0.99) on ILI between T1 and T3 across doses, indicating a reversal of cocaine's effect on ILI in T3 to predrug levels.
In contrast, a MANOVA on period between T1 and T2 revealed there was no significant three-way interaction among T1 to T2, dose, and levels of period (p > 0.82), and there was also no significant two-way T1 to T2 x dose interaction (p > 0.67) or main effect of T1 to T2 (p > 0.16). Thus, cocaine did not affect period in T2 with respect to T1, which was confirmed by graphic examination. At all doses, there was a similar distribution of periods between T1 and T2 at all levels of period from 83 to 267 ms, with a small but insignificant shift following cocaine injection: a smaller proportion of long periods and a larger proportion of short periods.
Therefore, following cocaine administration, lick duration and ILI both changed in a dose-dependent fashion but in opposite directions. That is, higher doses of cocaine tended to decrease lick duration while increasing ILI, particularly during stereotyped licking at dose 20. In addition to these changes, video analysis demonstrated that rats made significantly fewer long-distance licks in T2 (median = 13.0%) relative to T1 (median = 24.3%) at dose 20 (p < 0.05, Wilcoxon signed ranks test).
Neural Analysis
Dose- and Rate-Dependent Effects of Cocaine on Average Firing Rates in T2 and Reversal in T3. Seventy lick-related striatal neurons were recorded in 29 recording sessions from 18 rats. All neurons were histologically verified to be located in the ventrolateral striatum (Fig. 3). Of those 70 neurons, 20, 11, 17, and 22 were obtained at doses 0, 5, 10, and 20 mg/kg, respectively. A total of 1983 matched pairs between T1 and T2 were obtained from all 70 neurons. Of those matched pairs, 771, 267, 508, and 437 were from neurons at doses 0, 5, 10, and 20 mg/kg, respectively. Thus, the numbers of neurons and matched pairs were comparable across doses. Matched pairs of a representative neuron at dose 20 are shown in Table 1 to illustrate how matched pairs were yielded for individual neurons.
|
Table 2, top, presents results of modeling the changes in average FR of individual neurons by fitting an HLM on all matched pairs of all neurons. The HLM revealed a significant interaction of dose2 and the average T1FR (
05 =-0.003, p < 0.05) on the average T2FR of individual neurons, indicating that the changes in average firing rate of individual neurons from T1 to T2 were significantly different across doses and depended on the neuron's average T1FR. These effects are illustrated in Fig. 4 and, in addition, were further demonstrated using linear regression analysis between the average T1FRs and the average T2FRs of neurons at each dose. There was a strong linear relationship between the average T1FRs and the average T2FRs of neurons at doses 0 (R2 = 0.89, p < 0.001), 5 (R2 = 0.92, p < 0.001), and 10 (R2 = 0.90, p < 0.001) but not at dose 20 (R2 = 0.22, p < 0.05). Moreover, the slope of the regression line at dose 0 was not significantly different from 1 [slope = 0.917, 95% confidence interval (CI) = (0.757, 1.078)], indicating that the average T2FRs of neurons at dose 0 remained the same as their average T1FRs (Fig. 4A). In comparison, the slopes of the regression lines at dose 5 [slope = 0.79, 95% CI = (0.619, 0.961)], 10 [slope = 0.744, 95% CI = (0.608, 0.879)], and 20 [slope = 0.264, 95% CI = (0.031, 0.497)] were all significantly less than 1 with a decreasing trend as dose increased (Fig. 4, B–D), showing a "clockwise" rotation of between-neuron regression lines with increasing dose.
|
|
Notably, this dose-dependent pattern of clockwise rotation also demonstrates a firing rate-dependent effect of cocaine. At doses 5 and 10, the clockwise rotation of the regression lines was produced by increases in average T2FRs of slow firing neurons (i.e., neurons that exhibited average T1FRs < 1 impulses/s; Fig. 5A). At dose 20, both the increases in average T2FRs of slow firing neurons and the decreases in average T2FRs of fast firing neurons (average T1FRs > 1 impulses/s; Fig. 5B) together determined the greater clockwise rotation of the regression line.
To assess reversal of the altered average FR in T3, a total of 621 matched pairs between T1 and T3 were obtained from 28 neurons that exhibited stable neural activity in T3 at doses 5 (n = 9), 10 (n = 13), and 20 (n = 6). An HLM on these matched pairs revealed that there were neither significant interaction effects of dose and the average T1FR (dose x MT1FR and dose2 x MT1FR; p > 0.64) nor significant main effects of dose (dose and dose2; p > 0.7) on the average T3FR of individual neurons. Additional regression analysis at each of the cocaine doses showed that none of the slopes of the between-neuron linear regression lines that regressed neurons' average T3FRs against their average T1FRs was significantly different from 1 [dose 5, slope = 0.995, 95% CI = (0.789, 1.201); dose 10, slope = 0.918, 95% CI = (0.619, 1.215); dose 20, slope = 1.913, 95% CI = (-1.078, 4.905)]. These data demonstrate that neurons' average T3FRs were not significantly different from their average T1FRs at any dose (Fig. 5). Thus, the dose- and rate-dependent effects of cocaine on the average firing rates of individual neurons observed in T2 were no longer present in T3.
Dose- and Rate-Dependent Effects of Cocaine on Firing Rates of Matched Pairs within Individual Neurons in T2 and Reversal in T3. A two-way repeated-measures ANOVA on the S.D.s of T1FRs and T2FRs of matched pairs within neurons revealed that there was no significant interaction between T1 and T2 and dose [F(3,66) = 0.52, p > 0.67)] and no significant main effect of T1 and T2 [F(1,66) = 0.02, p > 0.88]. These data demonstrate that, although average FR of individual neurons systematically changed from T1 to T2 across doses as revealed by the HLM model (Fig. 4), the dispersion of FRs of matched pairs within individual neurons did not change from T1 to T2 in each dose.
Changes in firing rate of matched pairs within individual neurons were also analyzed by modeling the slope of the linear regression between T1FR and T2FR in the HLM (Table 2, bottom). Neither the interaction effects between dose and average T1FR (dose x MT1FR and dose2 x MT1FR; p > 0.24) nor the main effects of dose (dose and dose2; p > 0.05) were significant, indicating that matched pairs within neurons did not exhibit a dose-dependent pattern of change in FR. Moreover, the regression R2 values of matched pairs within neurons were low at each dose and did not differ across doses [F(3,66) = 2.20, p > 0.09; one-way ANOVA]. The average R2 value of all neurons at all doses was 0.12 ± 0.16 (mean ± S.D.). Therefore, within individual neurons at all doses, the T1FRs of matched pairs accounted for little variance in their T2FRs and had very low predictability on their T2FRs. This is consistent with our observation that, for a given matched pair of an individual neuron, its T2FR could be anywhere within the range of the T2FRs of all matched pairs of the neuron, regardless of the T1FR of the matched pair.
However, significant changes in FR emerged when matched pairs were separately analyzed in slow and fast firing neurons. Because cocaine's effects on average FR differed for these two types of neurons as described above, we analyzed slow and fast firing neurons separately with two ANCOVAs to test whether cocaine affected matched pairs within slow and fast firing neurons differently across doses. We further dichotomized matched pairs into low and high T1FR groups for each neuron to examine if low and high T1FR matched pairs exhibited different patterns of change in FR within individual neurons.
Thirty five neurons were categorized as slow firing, including 11, 6, 6, and 12 neurons from doses 0, 5, 10, and 20 mg/kg, respectively. At dose 0, a "regression to the mean" phenomenon, characterized by increased firing of low T1FR matched pairs and decreased firing of high T1FR matched pairs in T2, was observed within neurons (Figs. 6A and 7A). Across doses, there was a significant main effect of dose on FR of matched pairs from T1 to T2 [F(3,822) = 8.39, p < 0.0001, ANCOVA] but no interaction between dose and T1FR group (p > 0.15). Therefore, cocaine's effects on FR of the low and high T1FR matched pairs were similar across dose. Post hoc Bonferroni tests revealed significant enhancing effects on FR at doses 10 (p < 0.001) and 20 (p < 0.001) (Fig. 6A). Specifically, relative to the natural regression to the mean at dose 0, the low T1FR matched pairs showed greater increases, and the high T1FR matched pairs showed lesser decreases in firing rate from T1 to T2 at doses 10 and 20. These effects are illustrated by matched pairs of representative slow firing neurons at doses 10 and 20 (Fig. 7, E and G). Moreover, an analysis of reversal in T3 was performed separately for matched pairs at doses 10 (135 matched pairs from five neurons) and 20 (53 matched pairs from three neurons). The significant changes in FR form T1 to T2 were reversed in T3 at dose 10 (p < 0.001; Wilcoxon signed ranks test) but not at dose 20 (p > 0.89).
|
|
The remaining 35 neurons (9, 5, 11, and 10 at doses 0, 5, 10, and 20 mg/kg, respectively) were fast firing neurons. A similar regression to the mean was observed for matched pairs within neurons at dose 0 (Figs. 6B and 7B). ANCOVA revealed a significant main effect of dose on FR of matched pairs from T1 to T2 [F(3,1139) = 59.73, p < 0.0001] without an interaction between dose and T1FR group (p > 0.2), indicating a similar drug effect on low and high T1FR matched pairs across doses. However, in contrast to the enhancing effect on matched pairs within slow firing neurons, the high dose of cocaine suppressed both low and high T1FR matched pairs within fast firing neurons (Fig. 6B, p < 0.001, post-hoc Bonferroni tests). Specifically, relative to the regression to the mean at dose 0, low T1FR matched pairs showed decreases rather than increases in firing rate, whereas high T1FR matched pairs showed greater decreases in firing rate in T2 at dose 20. These effects are illustrated by matched pairs of a representative fast firing neuron at dose 20 (Fig. 7H). In addition, in T3, a reversal of cocaine's effect was found (p < 0.05; Wilcoxon signed ranks test) on 54 matched pairs between T1 and T3 obtained from three fast firing neurons at dose 20.
| Discussion |
|---|
|
|
|---|
Behavioral Effects. Psychomotor stimulants cause increased long-sequence movements at low doses and shorter, stereotyped movements at high doses (Bhattacharyya and Pradhan, 1979
). In the present paradigm, although licking was induced by water delivery, the highest dose of cocaine nonetheless induced stereotyped licking. This was evidenced by increased licking in the absence of water delivery, consistent with stereotypic effects observed in other studies (Lyon and Robbins, 1975
; Bhattacharyya and Pradhan, 1979
). This pattern of purposeless, repetitive movement is a defining characteristic of drug-induced stereotypy (Cooper and Dourish, 1990
).
Compared with predrug levels, cocaine simultaneously: 1) decreased the proportion of long lick durations while increasing the proportion of short durations and 2) increased the proportion of long ILI while decreasing the proportion of short ILI. These shifts in the frequency distributions of duration and ILI were more pronounced with increasing dose and subsequently reverted to predrug levels. Corresponding to decreased lick duration was a significant decrease in the distance of licks at the high dose. Reduced lick distance and duration are consistent: 1) with our previous finding that cocaine (20 mg/kg) decreased the proportion of long head movements (Pederson et al., 1997
), 2) with findings in other laboratories (Fowler and Mortell, 1992
), and 3) with the fact that striatal neurons phasically related to movement exhibit strong correlations with such parameters (Crutcher and De-Long, 1984
; Pederson et al., 1997
; Tang et al., 2007
).
Period was not altered by cocaine, reflecting the complementary, opposing changes in its two components, i.e., decreased lick duration and increased ILI. The consistent licking rhythm, which was not affected even by a dose (20 mg/kg) high enough to induce stereotypic licking, suggests that cocaine did not exert any apparent effects on brain stem mechanisms controlling licking rhythm (Wiesenfeld et al., 1977
; Brozek et al., 1996
; Travers et al., 1997
). Nonetheless, our observed trend (though not significant) toward fewer long periods and more short periods within bursts is in the same direction as Knowler and Ukena (1973
) observed at low doses in their sample of three rats. In another sample of three monkeys, amphetamine-induced increases in licking rate were inversely related to control rate (Wuttke, 1970
). However, lick rate is not simply the inverse of within-burst period. We analyzed period only within bursts of licking (period
270 ms) but did not assess overall rate due to the fact that a small percentage of licks failed to break the light beam.
Dose- and Firing Rate-Dependent Effects on Firing. At zero dose (saline), average firing rates did not change after injection, represented by a regression line between T1 and T2 average firing rates that was not different from a line of no change. At low and moderate doses, slow firing neurons exhibited increased firing rates, resulting in a clockwise rotation of the regression line. At the high dose, which induced stereotypic licking, the regression line rotated clockwise to the greatest degree, determined by both the increased firing of slow firing neurons and the decreased firing of fast firing neurons. These dose-dependent changes in firing were not present during the 3rd h following cocaine administration, at which time behavior also returned to predrug levels.
Moreover, cocaine's effects on firing associated with matched pairs of individual types of licks were also dose- and rate-dependent, underlying the observed changes in average firing rate. At zero dose, matched pairs with lower firing rates in T1 tended to increase firing in T2 and those with higher firing rates in T1 tended to decrease firing in T2. These combined to yield no change in average firing rate after saline injection. This regression to the mean was observed in matched pairs of both slow and fast firing neurons, consistent with the natural and spontaneous fluctuations in phasic firing exhibited by sensorimotor striatal neurons (Prokopenko et al., 2004
). In contrast, significant and differential effects were observed on matched pairs of individual slow and fast firing neurons following cocaine injection.
For slow firing neurons at the middle and high doses, matched pairs with lower predrug firing rates exhibited a greater increase, and those with higher predrug firing rates exhibited a lesser decrease in firing, compared with the saline group. Thus, firing of all matched pairs was elevated above control at these two doses, underlying the increased average firing rate of slow firing neurons.
For fast firing neurons, however, the high dose of cocaine suppressed firing of all matched pairs, especially those with higher predrug firing rates, underlying the decreased average firing rate of these neurons at this dose. Thus, suppressed firing rates were observed only for fast firing neurons, especially for their highest firing rates, and only at the high dose.
Potentially analogous to the observation of Dews (1958
) of rate-dependent effects of stimulants on behavior, cocaine's effect depended on an individual neuron's normal firing rate. Slow firing neurons exhibited a generally greater tendency to discharge at moderate and high doses, their low firing rates more elevated and their high firing rates less reduced than predicted by the regression to the mean observed for controls. Fast firing neurons exhibited the opposite, i.e., a generally lower tendency to discharge at the high dose, both their low and high firing rates strongly reduced compared with controls. Notably, their highest firing rates exhibited the greatest reductions.
The present dose- and rate-dependent patterns of striatal activity during cocaine-induced stereotypic licking help to sort out the mixture of increases and decreases in firing rates observed in previous studies of effects of psychomotor stimulants on striatal neurons during behavior (Trulson and Jacobs, 1979
; Gardiner et al., 1988
; Haracz et al., 1989
; Ryan et al., 1989
; Pederson et al., 1997
; West et al., 1997
). It appears that predrug firing rate is an important factor to consider in such studies. According to the present findings, dose-dependent changes in a neuron's average firing rate would be predicted by its predrug average. Slow firing neurons would on average exhibit elevated firing rates at all doses. Moreover, an individual slow firing neuron would exhibit dose-dependent elevations only for its normally low, but not its high, firing rates. For a fast firing neuron, both its normally low firing rates, and to an even greater extent its normally high firing rates would be suppressed by high doses capable of inducing stereotypic movement. Indeed, initial firing rate may be important in a more general sense, as demonstrated by our finding that the initial firing rate of striatal neurons is correlated with their rate of change in firing during motor habit learning (Tang et al., 2007
).
We previously reported that striatal head movement neurons exhibited similar rate-dependent changes in movement-related firing after cocaine administration (Pederson et al., 1997
). Recently, we found that these drug effects were also dose-dependent when compared with a saline group (unpublished data). These studies and the present one independently demonstrate consistent firing rate- and dose-dependent effects of cocaine on movement-related striatal firing in different populations of striatal neurons associated with different stereotyped behaviors. Cocaine's effects on both slow and fast firing neurons may be involved in producing stereotypy. At a high dose, the elevation of low striatal firing rates may stimulate motor and premotor areas to initiate movements, whereas the simultaneous suppression of high firing rates may reduce the likelihood of long-sequence or exploratory movements. Other psychomotor stimulants (e.g., amphetamine) may also influence striatal firing during stereotypy in a similar dose- and rate-dependent manner (Trulson and Jacobs, 1979
; West et al., 1997
). This hypothesis needs to be validated in future studies.
The present elevation of low average firing rates and reduction of high average firing rates at the high dose suggests that, under conditions of elevated striatal dopamine transmission by cocaine (Nicolaysen et al., 1988
; Czoty et al., 2000
; Stuber et al., 2005
), there is a reduced range in overall sensorimotor output. We have previously reported that under opposite conditions the range of striatal sensorimotor firing increased. That is, following microinjection of apomorphine into the substantia nigra to reduce striatal dopamine transmission via autoreceptor-mediated inhibition of dopamine cell firing, striatal firing in response to somatosensory stimulation exhibited greater than normal fluctuations (Prokopenko et al., 2004
). Together, these findings suggest that a regulatory role of striatal dopamine may be to restrict the range of corticostriatal throughput. This is inconsistent with hypotheses that striatal dopamine acts to weaken throughput of weak cortical inputs and strengthen throughput of strong cortical inputs (Nicola et al., 2000
; O'Donnell, 2003
; Bamford et al., 2004
). Indeed, the fastest firing rates (presumably reflecting strong cortical input) were the most reduced by cocaine in the present study. It must be noted that these findings do not reflect a singular action of cocaine on striatal dopamine but also likely reflect the summation of peripheral and central effects exerted by systemic cocaine, which may include attenuation of strong somatosensory thalamocortical signaling (Rutter et al., 2005
).
| Acknowledgements |
|---|
| Footnotes |
|---|
Article, publication date, and citation information can be found at http://jpet.aspetjournals.org.
ABBREVIATIONS: DA, dopamine; T1, precocaine time epoch; T2, cocaine time epoch; T3, recovery time epoch; ANOVA, analysis of variance; ILI, interlick interval; MANOVA, multivariate analysis of variance; PETH, perievent time histogram; FR, firing rate; HLM, hierarchical linear model; ANCOVA, analysis of covariance; CI, confidence interval.
1 Current affiliation: Center for Neurosciences, The Feinstein Institute for Medical Research, North Shore-Long Island Jewish Health System, Manhasset, New York. ![]()
Address correspondence to: Dr. Mark O. West, Department of Psychology, Rutgers University, 152 Frelinghuysen Road, New Brunswick, NJ 08854. E-mail: markwest{at}rutgers.edu
| References |
|---|
|
|
|---|
Bamford NS, Zhang H, Schmitz Y, Wu NP, Cepeda C, Levine MS, Schmauss C, Zakharenko SS, Zablow L, and Sulzer D (2004) Heterosynaptic dopamine neuro-transmission selects sets of corticostriatal terminals. Neuron 42: 653-663.[CrossRef][Medline]
Bhattacharyya AK and Pradhan SN (1979) Interactions between motor activity and stereotypy in cocaine-treated rats. Psychopharmacology 63: 311-312.[CrossRef][Medline]
Brozek G, Zhuravin IA, Megirian D, and Bures J (1996) Localization of the central rhythm generator involved in spontaneous consummatory licking in rats: functional ablation and electrical brain stimulation studies. Proc Natl Acad Sci U S A 93: 3325-3329.
Bryk AS and Raudenbush SW (2002) Hierarchical Linear Models: Applications and Data Analysis Methods, Sage Publications, Thousand Oaks, CA.
Cho J and West MO (1997) Distribution of single neurons related to body parts in the lateral striatum of the rat. Brain Res 756: 241-246.[CrossRef][Medline]
Cooper SJ and Dourish CT (1990) An introduction to the concept of stereotypy and a historical perspective on the role of brain dopamine, in Neurobiology of stereo-typed behavior (Cooper SJ and Dourish CT eds) pp 1-24, Oxford University Press, New York.
Creese I and Iverson SD (1973) Blockade of amphetamine induced motor stimulation and stereotypy in the adult rat following neonatal treatment with 6-hydroxydopamine. Brain Res 55: 369-382.[CrossRef][Medline]
Crutcher MD and DeLong MR (1984) Single cell studies of the primate putamen: I. Functional organization. Exp Brain Res 53: 233-243.[Medline]
Czoty PW, Justice JB Jr, and Howell LL (2000) Cocaine-induced changes in extracellular dopamine determined by microdialysis in awake squirrel monkeys. Psychopharmacol (Berl) 148: 299-306.[CrossRef][Medline]
Delfs JM and Kelley AE (1990) The role of D1 and D2 dopamine receptors in oral stereotypy induced by dopaminergic stimulation of the ventrolateral striatum. Neuroscience 39: 59-67.[CrossRef][Medline]
Dews PB (1958) Studies on behavior: IV. Stimulant actions of methamphetamine. J Pharmacol Exp Ther 122: 137-147.
Fowler SC and Mortell C (1992) Low doses of haloperidol interfere with rat tongue extensions during licking: a quantitative analysis. Behav Neurosci 106: 386-395.[CrossRef][Medline]
Gardiner TW, Iverson DA, and Rebec GV (1988) Heterogeneous responses of neostriatal neurons to amphetamine in freely moving rats. Brain Res 463: 268-274.[CrossRef][Medline]
Haracz JL, Tschanz JT, Wang Z, White IM, and Rebec GV (1993) Striatal single unit responses to amphetamine and neuroleptics in freely moving rats. Neurosci Biobehav Rev 17: 1-12.[CrossRef][Medline]
Haracz JL, Tschanz JT, Greenberg J, and Rebec GV (1989) Amphetamine-induced excitations predominate in single neostriatal neurons showing motor-related activity. Brain Res 489: 365-368.[CrossRef][Medline]
Heikkila RE, Cabbat FS, and Duvoisin RC (1979) Motor activity and rotational behavior after analogs of cocaine: correlation with dopamine uptake blockade. Commun Psychopharmacol 3: 285-290.[Medline]
Kelley AE, Lang CG, and Gauthier AM (1988) Induction of oral stereotypy following amphetamine microinjection into a discrete subregion of the striatum. Psychopharmacology 95: 556-559.[Medline]
Knowler WC and Ukena TE (1973) The effects of chlorpromazine, pentobarbital, chlordiazepoxide and D-amphetamine on rates of licking in the rat. J Pharmacol Exp Ther 184: 385-397.
Lyon M and Robbins T (1975) The action of central nervous system stimulant drugs: a general theory concerning amphetamine effects, in Current Developments in Psychopharmacology (Essman WB and Valzelli L eds) pp 79-163, Spectrum Publications, New York.
Mittler T, Cho J, Peoples LL, and West MO (1994) Representation of the body in the lateral striatum of the freely moving rat: single neurons related to licking. Exp Brain Res 98(1): 163-167.[Medline]
Mosteller F and Tukey JW (1977) Data Analysis and Regression: A Second Course in Statistics, Addison-Wesley Publishing Co. Inc., Menlo Park, CA.
Nicola SM, Surmeier J, and Malenka RC (2000) Dopaminergic modulation of neuronal excitability in the striatum and nucleus accumbens. Annu Rev Neurosci 23: 185-215.[CrossRef][Medline]
Nicolaysen LC, Pan H, and Justice JB Jr (1988) Extracellular cocaine and dopamine concentrations are linearly related in rat striatum. Brain Res 456: 317-323.[CrossRef][Medline]
Nisenbaum ES, Orr WB, and Berger TW (1988) Evidence for two functionally distinct subpopulations of neurons within the rat striatum. J Neurosci 8: 4138-4150.[Abstract]
O'Donnell P (2003) Dopamine gating of forebrain neural ensembles. Eur J Neurosci 17: 429-435.[CrossRef][Medline]
Paxinos G and Watson C (2005) The Rat Brain in Stereotaxic Coordinates, Academic, New York.
Pederson CL, Wolske M, Peoples LL, and West MO (1997) Firing rate dependent effect of cocaine on single neurons of the rat lateral striatum. Brain Res 760: 261-265.[CrossRef][Medline]
Peoples LL and West MO (1996) Phasic firing of single neurons in the rat nucleus accumbens correlated with the timing of intravenous cocaine self-administration. J Neurosci 16: 3459-3473.
Prokopenko VF, Pawlak AP, and West MO (2004) Fluctuations in somatosensory responsiveness and baseline firing rates of neurons in the lateral striatum of freely moving rats: effects of intranigral apomorphine. Neuroscience 125: 1077-1082.[CrossRef][Medline]
Rebec GV and Segal DS (1978) Dose-dependent biphasic alterations in the spontaneous activity of neurons in the rat neostriatum produced by D-amphetamine and methylphenidate. Brain Res 150: 353-366.[CrossRef][Medline]
Rutter JJ, Devilbiss DM, and Waterhouse BD (2005) Effects of systemically administered cocaine on sensory responses to peri-threshold vibrissae stimulation: individual cells, ensemble activity, and animal behaviour. Eur J Neurosci 22: 3205-3216.[CrossRef][Medline]
Ryan LJ, Young SJ, Segal DS, and Groves PM (1989) Antidromically identified striatonigral projection neurons in the chronically implanted behaving rat: relations of cell firing to amphetamine-induced behaviors. Behav Neurosci 103: 3-14.[CrossRef][Medline]
Stuber GD, Roitman MF, Phillips PE, Carelli RM, and Wightman RM (2005) Rapid dopamine signaling in the nucleus accumbens during contingent and noncontingent cocaine administration. Neuropsychopharmacology 30: 853-863.[CrossRef][Medline]
Tang C, Pawlak AP, Prokopenko V, and West MO (2007) Changes in activity of the striatum during formation of a motor habit. Eur J Neurosci 25: 1212-1227.[CrossRef][Medline]
Travers JB, Dinardo LA, and Karimnamazi H (1997) Motor and premotor mechanisms of licking. Neurosci Biobehav Rev 21: 631-647.[CrossRef][Medline]
Trulson ME and Jacobs BL (1979) Effects of D-amphetamine on striatal unit activity and behavior in freely moving cats. Neuropharmacology 18: 735-738.[CrossRef][Medline]
West MO (1998) Anesthetics eliminate somatosensory-evoked discharges of neurons in the somatotopically organized sensorimotor striatum of the rat. J Neurosci 18: 9055-9068.
West MO, Peoples LL, Michael AJ, Chapin JK, and Woodward DJ (1997) Low-dose amphetamine elevates movement-related firing of rat striatal neurons. Brain Res 745: 331-335.[CrossRef][Medline]
Wiesenfeld Z, Halpern BP, and Tapper DN (1977) Licking behavior: evidence of hypoglossal oscillator. Science 196: 1122-1124.
Wuttke W (1970) The effects of D-amphetamine on schedule-controlled water licking in the Squirrel monkey. Psychopharmacologia 17: 70-82.[CrossRef][Medline]
This article has been cited by other articles:
![]() |
C. C. Tang, D. H. Root, D. C. Duke, Y. Zhu, K. Teixeria, S. Ma, D. J. Barker, and M. O. West Decreased Firing of Striatal Neurons Related to Licking during Acquisition and Overtraining of a Licking Task J. Neurosci., November 4, 2009; 29(44): 13952 - 13961. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. R. Tilley and H. H. Gu The Effects of Methylphenidate on Knockin Mice with a Methylphenidate-Resistant Dopamine Transporter J. Pharmacol. Exp. Ther., November 1, 2008; 327(2): 554 - 560. [Abstract] [Full Text] [PDF] |
||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||